Tuesday, 22. May 2012 | 00:26 h

 
 

LSS (SCY)

lss-scyTwin flat cables with PVC insulation in colour or transparent design

Technical data: LSS (SCY)



CONSTRUCTION
Conductor: Stranded copper conductor, class 5
Insulation: PVC in colour or transparent design, one core with a protrusion

TECHNICAL SPECIFICATION
Rated voltage 100 V
Test voltage 1 kV
Perm. operating temperature
min. -40 °C max. +70 °C - red/black insulation
min. -15 °C max. +70 °C - transparent insulation
Min. perm. temp. for installation and handling 0 °C
Max. perm. storage temperature +40 °C
Use: Twin flat cables for audio systems.
Colour of sheath red/black or transparent
Standard packing
Coils in foil 200 m (cros-section up to 1 mm2)
Coils in foil 100 m (cross-section from 1,5 mm2)